MM780G full system transparent
novopen

Summary

The Medtronic MiniMed™ 780G system is designed with SmartGuard™ technology, which can help with the occasionally missed meal or inexact carb counts. It provides automatic basal adjustments to manage glucose levels to a prespecified target (100 mg/dL [5.5 mmol/L], 110 mg/dL [6.1 mmol/L], or 120 mg/dL [6.7 mmol/L]) and auto correction bolus, every 5 minutes.  The advanced hybrid closed-loop system uses current and past glucose trends from the Guardian™ 4 sensor to detect a rapid rise (e.g., a missed meal) in sensor glucose.  No fingersticks required when the SmartGuard™ feature is active.

NovoPen 6 & NovoPen Echo Plus provides the smart addition of a personal injection log. Both pens are compatible with Novo Nordisk insulins in Penfill 3 ml cartridges and work with NovoFine single-use disposable needles. You can transfer your insulin dosing information from your smart pen to your device using the app. 

Components

Medtronic 780G : Pump

Medtronic 780G : Pump

Pump connects tubing to a small patch called an infusion set that attaches to the body.

Medtronic 780G : Sensor

Medtronic 780G : Sensor

Sensor is inserted underneath the skin, either on the abdomen or arm.

Medtronic 780G : Controller

Medtronic 780G : Controller

Pump receives CGM readings and automatically adjusts insulin delivery. Data from the pump and CGM viewable on compatible smartphones.

Medtronic 780G : Infusion Set

Medtronic 780G : Infusion Set

An infusion set contains the thin plastic tubing that delivers insulin from the pump to the body.

NovoPen 6/NovoPen Echo : Sensor

NovoPen 6/NovoPen Echo : Sensor

Sensor uses a thin, flexible filament inserted just under the skin to measure glucose levels every 5 minutes. Push-button applicator allows sensor to be placed on the body in one step.

NovoPen 6/NovoPen Echo : Controller

NovoPen 6/NovoPen Echo : Controller

Smart pen records daily injections and sends them to the compatible app by tapping the device with a compatible smartphone.

NovoPen 6/NovoPen Echo : Receiver

NovoPen 6/NovoPen Echo : Receiver

Smart pen and sensor readings displays dosage information directly on smart mobile device.

Device Details

Overview

This system is integrated and has a customizable settings. Many providers are familiar with Medtronic products. 

Discreet and modern option for people using multiple daily injections.

Affordability and Access

$$$$
Coverage information is not yet available. Price range; $0-10,769 to start and $0-$300/Month. Price range varies depending on insurance coverage. 

 

$$$$
Sometimes covered. NovoPens are covered by some commercial insurance companies; typically, users pay $21 out-of-pocket copays for the eight-month device. Prices range from $0- $78. For those without any insurance coverage, a single pen price is $78.

Data Monitoring Options

Yes
CareLink connect is available for care partners with up to five people who can follow a pump user and receive high and low notifications to help keep everyone in the loop.

Yes
Hold the dose memory of the pen straight against the Near Field Communication (NFC) spot on your device. Wait while your injection details are automatically transferred to a compatible app on your device. Compatible with multiple data monitoring platforms, including Glooko, MySugr, and Dose Check

Data View Options

Yes
Data is viewed on compatible smart devices through the MiniMed Mobile App. You can download and view pump or CGM data on CareLink.

Yes
Dose-related data can be viewed on the NovoPen 6 & NovoPen Echo apps. 

Duration and Storage

7-day pump 7-day sensor
Sensors last 7 days, transmitter needs weekly charging, store between 36 °F - 86 °F. Pump can be used for up to 7 days with the extended infusion set and works between 40ºF - 104ºF. 

28-day pen (Compatible with 10-day or 14-day sensor)
Sensor lasts for 10-14 days depending on the brand, insulin pen lasts for up to 28 days. Pen has 800-injection dose memory and a five-year battery life. Sensor works between 50ºF - 113ºF and pens can be kept at room temperature for up to 28 days. 

 

Vision / Auditory / Dexterity

NO text to speech
YES 
vibration alerts
A LOT 
of dexterity needed

NO text to speech
NO vibration alerts
A LOT of dexterity needed

Patient Considerations

Active Lifestyle

Temp Target. Manually increase blood sugar target range to 150 mg/dl during activity. Temp target can run 30 minutes to 24 hours in 30-minute increments. Auto corrections are disabled. The pump is not waterproof.

Light on body. Pens are easy to use and do not remain attached to the body, senor is light on the body.

Avoiding Highs and Lows

Customizable auto-bolus. Auto-correct bolus corrects highs if carb counts are miscalculated or bolus is occasionally missed. The system aims to maintain a target blood glucose level between 100 mg/dL and 120 mg/dL depending on personalized target glucose settings. Auto-bolus is available every 5 minutes to correct blood sugar between 100 mg/dL and 120 mg/dL (12 corrections per hour). Automatic insulin delivery settings are adjustable.

Limited customizability. System integrates the Dexcom G6/G7 or Libre CGM for high or low alerts but requires manual dose adjustment and limits the ability to adjust insulin levels throughout the day. 

Comfort

Somewhat comfortable. Medtronic sensors need more tape than other sensors. Largest pump option. 

Many components. Have to carry pens and pen needles. CGM is attached to the body.

Easy Insulin Dosing

Automatically adjusts settings. Automatically adjusts insulin to reach personalized target between 100 mg/dL and 120 mg/dL. Will automatically revert to manual mode in certain situations. Basal and bolus in 0.025 increments. Extended bolus unavailable when using automated insulin delivery mode. 

NovoPen 6The maximum dose is 60 units, and doses increase in 1-unit increments. NovoPen Echo PlusThe maximum dose is 30 units, and doses increase in 0.5-unit increments

Easy to Use

Easy software. Software makes many dosing decisions. Can be difficult to keep automatic insulin dosing features working. Requires fewer parts than do-it-yourself systems.

Simple design. Replaces regular insulin pen. No additional devices to add on. 

Fewer Fingersticks

Factory-calibrated sensor. Fingersticks needed for backup only.

Factory-calibrated sensor. Finger sticks needed for backup only. 

Privacy

Somewhat discrete. Ability to check blood sugar on phone or watch. Pump has tubing but can be clipped to clothing or placed in a pocket to be discreet when needed. 

Hideable. Pens are portable but visible when in use. Frequent injections are unavoidable. View recommendations and data on a smartphone.