medtronic sensor sync device image
medtronic sensor sync device image

Summary

This is a disposable, all-in-one CGM sensor integrated with Medtronic’s pump systems (e.g., MiniMed 780G). Typical wear time is 6 days, plus a 24-hour “grace period.” No routine fingersticks are required when the device is in closed-loop/SmartGuard mode.

FDA approved for ages 7+ on the back of the upper arm

MARD of ~9%

This is a disposable, all-in-one CGM sensor integrated with Medtronic’s pump systems (e.g., MiniMed 780G). Typical wear time is 6 days, plus a 24-hour “grace period.” No routine fingersticks are required when the device is in closed-loop/SmartGuard mode.

FDA approved for ages 7+ on the back of the upper arm

MARD of ~9%

Components

Medtronic Simplera Sync : Sensor

Medtronic Simplera Sync : Sensor

Sensor uses a thin, flexible filament beneath the skin to continuously measure glucose every 5 minutes. Simple, one-step applicator makes insertion fast and easy.

Medtronic Simplera Sync : Sensor

Medtronic Simplera Sync : Sensor

Sensor uses a thin, flexible filament beneath the skin to continuously measure glucose every 5 minutes. Simple, one-step applicator makes insertion fast and easy.

Device Details

Overview

Disposable, all-in-one CGM sensor integrated with Medtronic’s pump systems

Disposable, all-in-one CGM sensor integrated with Medtronic’s pump systems

Affordability and Access

$$$$
Coverage depends on region and insurance; supplied via DME or specialty pharmacy.

$$$$
Coverage depends on region and insurance; supplied via DME or specialty pharmacy.

Data Monitoring Options

Yes
Data streams directly to the pump; users and clinicians can view trends and logs via Medtronic’s platforms.

Yes
Data streams directly to the pump; users and clinicians can view trends and logs via Medtronic’s platforms.

Data View Options

Yes
Data view directly on your connected pump or smart device. 

Yes
Data view directly on your connected pump or smart device. 

Duration and Storage

6 Days
Sensors last 6 days, with a 24-hour grace period, and need about 2 hours to warm up. They work between 41°F – 104°F and should be stored between 36°F – 86°F. They are usually shipped in 1–3 month supplies, which is about 5–15 sensors at a time.

6 Days
Sensors last 6 days, with a 24-hour grace period, and need about 2 hours to warm up. They work between 41°F – 104°F and should be stored between 36°F – 86°F. They are usually shipped in 1–3 month supplies, which is about 5–15 sensors at a time.

Vision / Auditory / Dexterity

YES text to speech
YES vibration alerts
Multiple sound sources
Moderate dexterity needed

YES text to speech
YES vibration alerts
Multiple sound sources
Moderate dexterity needed

Patient Considerations

Active Lifestyle

Compact and integrated. Reducing bulk; compatibility with daily activities depends on the adhesive and body movement. Water-resistant up to 8 feet (2.4 m) for 30 minutes.

Compact and integrated. Reducing bulk; compatibility with daily activities depends on the adhesive and body movement. Water-resistant up to 8 feet (2.4 m) for 30 minutes.

Avoiding Highs and Lows

SmartGuard closed-loop. Pump adjustments use sensor data continuously to reduce highs and lows.

SmartGuard closed-loop. Pump adjustments use sensor data continuously to reduce highs and lows.

Comfort

Low profile. No overtape needed and one-hand insertion.

Low profile. No overtape needed and one-hand insertion.

Easy Insulin Dosing

SmartGuard technology. When paired with the MiniMed 780G, it automatically adjusts basal and gives correction boluses based on sensor readings. In manual mode, glucose values can guide dosing decisions, but fingersticks are required for confirmation.

SmartGuard technology. When paired with the MiniMed 780G, it automatically adjusts basal and gives correction boluses based on sensor readings. In manual mode, glucose values can guide dosing decisions, but fingersticks are required for confirmation.

Easy to Use

All-in-one. Eliminates the need for a separate transmitter, simplifying sensor changes (although more frequent due to the 6-day wear).

All-in-one. Eliminates the need for a separate transmitter, simplifying sensor changes (although more frequent due to the 6-day wear).

Fewer Fingersticks

Calibration is optional. Perfect if you like having that choice.

Calibration is optional. Perfect if you like having that choice.

Privacy

Small and integrated, but visible on the back of the arm. No separate transmitter reduces the number of visible parts. Alerts and alarms can be adjusted for discretion.