Are you a healthcare professional who takes care of people with diabetes? Visit Pro.DiabetesWise.org

Lo que se necesita para comenzar

Pump

Pump connects tubing to a small patch called an infusion set that attaches to the body.

Sensor

Sensor is inserted underneath the skin, either on the abdomen or arm.

Controller

Pump receives CGM readings and automatically adjusts insulin delivery. Data from the pump and CGM viewable on compatible smartphones.

Infusion Set

An infusion set contains the thin plastic tubing that delivers insulin from the pump to the body.

Ver y Aprender

Introduction to Medtronic 770G System

Inserting the Infusion Set

Using the Medtronic 770G System

Detalles del dispositivo

Affordability and Access

$$$$
Widely covered for insulin-dependent type 1 and 2. Sensor and pump provided by DME. Price range; $0-$8,574 to start and $0-$300/Month. Price range varies depending on insurance coverage.

Data Monitoring Options

Yes
CareLink connect is available for care partners with up to five people who can follow a pump user and receive high and low notifications to help keep everyone in the loop.

Data View Options

Yes
Guardian sensor data is viewed on the pump's main screen. You can download and view pump or CGM data on CareLink.

Duration and Storage

3-day pump 7-day sensor
Sensors last 7 days, transmitter needs weekly charging, store between 36 °F - 86 °F. Pump can be used for up to 72 hours and works between 40ºF - 104ºF.

Vision / Auditory / Dexterity

NO text to speech
YES 
vibration alerts
A LOT 
of dexterity needed

Consideraciones del paciente

Confort

Somewhat comfortable. Medtronic sensors need more tape than other sensors. Largest pump option. 

Estilo de Vida Activo

Exercise mode. Manually increase blood sugar target range to 150 mg/dl during activity. System responds to blood sugar changes during activity automatically. Pump is not waterproof.

Evitar los Altibajos

Limited auto-basal. Auto-basal only responds to hyperglycemia to maintain a target blood glucose level between 100 mg/dl and 120 mg/dl. Auto-basal is available every 5-minutes to correct blood sugar above 120 mg/dl (12 corrections per hour). Automatic insulin delivery settings are not adjustable. Auto-bolus is not available. 

Fácil de Usar

Easy software. Software makes many dosing decisions. Can be difficult to keep automatic insulin dosing features working. Requires fewer parts than do-it-yourself systems.

Fácil Dosificación de Insulina

Automatically adjusts settings. Automatically adjusts insulin to reach one of two preset targets. Will automatically revert to manual mode in certain situations. Basal and bolus in 0.025 increments. Extended bolus unavailable when using automated insulin delivery mode. 

Menos Pinchazos en Los Dedos

2 daily fingersticks are needed to calibrate the sensor.

Privacidad

Somewhat discrete. Ability to check blood sugar on phone or watch. Pump has tubing but can be clipped to clothing or placed in a pocket to be discreet when needed.